MidnightBSD

Advisories for barco

CVE-2016-3149 HIGH

Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors.

CVSS 2.0

Severity: HIGH

Problem Type: NVD-CWE-noinfo,

Products Affected

Vendor Product Version
barco clickshare_csc-1_firmware *
barco clickshare_csm-1_firmware *
CVE-2016-3150 MEDIUM

Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-79,

Products Affected

Vendor Product Version
barco clickshare_csc-1_firmware *
barco clickshare_cse-200_firmware *
CVE-2016-3151 MEDIUM

Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-22,

Products Affected

Vendor Product Version
barco clickshare_csc-1_firmware *
barco clickshare_csm-1_firmware *
barco clickshare_cse-200_firmware *
CVE-2016-3152 MEDIUM

Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-200,

Products Affected

Vendor Product Version
barco clickshare_csc-1_firmware *
CVE-2017-12460 LOW

An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10. An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product. By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output.

CVSS 2.0

Severity: LOW

Problem Type: CWE-79,

Products Affected

Vendor Product Version
barco clickshare_csc-1_firmware *
barco clickshare_csm-1_firmware *
CVE-2017-9377 HIGH

A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-78,

Products Affected

Vendor Product Version
barco clickshare_csc-1_firmware *
barco clickshare_csm-1_firmware *
CVE-2018-10943 HIGH

An issue was discovered on Barco ClickShare CSE-200 and CS-100 Base Units with firmware before 1.6.0.3. Sending an arbitrary unexpected string to TCP port 7100 respecting a certain frequency timing disconnects all clients and results in a crash of the Unit.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-20,

Products Affected

Vendor Product Version
barco clickshare_cs-100_firmware *
barco clickshare_cse-200_firmware *