In BASETech GE-131 BT-1837836 firmware 20180921, the web-server on the system is configured with the option “DocumentRoot /etc“. This allows an attacker with network access to the web-server to download any files from the “/etc” folder without authentication. No path traversal sequences are needed to exploit this vulnerability.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N | 3.9 | 3.6 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-22,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| basetech | ge-131_bt-1837836_firmware | 20180921 |
Cleartext Transmission of Sensitive Information vulnerability in BASETech GE-131 BT-1837836 firmware 20180921 exists which could leak sensitive information transmitted between the mobile app and the camera device.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N | 3.9 | 3.6 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-319,CWE-522,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| basetech | ge-131_bt-1837836_firmware | 20180921 |
Use of default credentials for the telnet server in BASETech GE-131 BT-1837836 firmware 20180921 allows remote attackers to execute arbitrary system commands as the root user.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 9.8 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | 3.9 | 5.9 |
CVSS 2.0
Severity: HIGH
Problem Type: CWE-1188,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| basetech | ge-131_bt-1837836_firmware | 20180921 |
A predictable device ID in BASETech GE-131 BT-1837836 firmware 20180921 allows unauthenticated remote attackers to connect to the device.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N | 3.9 | 1.4 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-330,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| basetech | ge-131_bt-1837836_firmware | 20180921 |
Unprotected Storage of Credentials vulnerability in BASETech GE-131 BT-1837836 firmware 20180921 allows local users to gain access to the video streaming username and password via SQLite files containing plain text credentials.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 5.5 | MEDIUM | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N | 1.8 | 3.6 |
CVSS 2.0
Severity: LOW
Problem Type: CWE-522,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| basetech | ge-131_bt-1837836_firmware | 20180921 |
Use of an undocumented user in BASETech GE-131 BT-1837836 firmware 20180921 allows remote attackers to view the video stream.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 6.5 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N | 2.8 | 3.6 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-287,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| basetech | ge-131_bt-1837836_firmware | 20180921 |