MidnightBSD

Advisories for bender

CVE-2019-19885 MEDIUM

In Bender COMTRAXX, user authorization is validated for most, but not all, routes in the system. A user with knowledge about the routes can read and write configuration data without prior authorization. This affects COM465IP, COM465DP, COM465ID, CP700, CP907, and CP915 devices before 4.2.0.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N 3.9 5.2

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-862,

Products Affected

Vendor Product Version
bender com465dp_firmware *
bender cp915_firmware *
bender cp907_firmware *
bender com465id_firmware *
bender com465ip_firmware *
bender cp700_firmware *
CVE-2021-34587 MEDIUM

In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L 3.9 1.4
info@cert.vde.com 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L 3.9 1.4

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-121,CWE-787,

Products Affected

Vendor Product Version
bender cc613_firmware *
ibm _ibm_rational_lifecycle_integration_adapter_for_windchill 1.0.0
bender icc16xx_firmware *
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34588 MEDIUM

In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty after reboot .

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N 3.9 4.0
info@cert.vde.com 8.6 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N 3.9 4.0

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-425,

Products Affected

Vendor Product Version
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34589 MEDIUM

In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
info@cert.vde.com 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 3.9 3.6
nvd@nist.gov 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 3.9 3.6

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-200,

Products Affected

Vendor Product Version
bender icc613_firmware *
bender cc613_firmware *
bender icc16xx_firmware *
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34590 LOW

In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values are not properly escaped when displayed.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
info@cert.vde.com 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N 2.3 2.7
nvd@nist.gov 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N 2.3 2.7

CVSS 2.0

Severity: LOW

Problem Type: CWE-79,

Products Affected

Vendor Product Version
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34591 HIGH

In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip udhcpc and ifplugd.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 1.8 5.9
info@cert.vde.com 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 1.8 5.9

CVSS 2.0

Severity: HIGH

Problem Type: CWE-250,

Products Affected

Vendor Product Version
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34592 MEDIUM

In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 2.8 5.9
info@cert.vde.com 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 2.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-77,

Products Affected

Vendor Product Version
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34601 HIGH

In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 3.9 5.9
info@cert.vde.com 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 3.9 5.9

CVSS 2.0

Severity: HIGH

Problem Type: CWE-259,CWE-798,

Products Affected

Vendor Product Version
bender icc15xx_firmware *
bender cc612_firmware *
CVE-2021-34602 MEDIUM

In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 2.8 5.9
info@cert.vde.com 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 2.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-78,

Products Affected

Vendor Product Version
bender icc15xx_firmware *
bender cc612_firmware *