MidnightBSD

Advisories for cru-inc

CVE-2013-6881 HIGH

CRU Ditto Forensic FieldStation with firmware before 2013Oct15a allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) sector size or (2) skip count fields for the forensic imaging task.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-78,

Products Affected

Vendor Product Version
cru-inc ditto_forensic_fieldstation -
cru-inc ditto_forensic_fieldstation_firmware *
CVE-2013-6882 MEDIUM

Multiple cross-site scripting (XSS) vulnerabilities in CRU Ditto Forensic FieldStation with firmware 2013Oct15a and earlier allow (1) remote attackers to inject arbitrary web script or HTML via the username parameter in a login or (2) remote authenticated users to inject arbitrary web script or HTML via unspecified form fields.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-79,

Products Affected

Vendor Product Version
cru-inc ditto_forensic_fieldstation -
cru-inc ditto_forensic_fieldstation_firmware *
CVE-2013-6883 MEDIUM

Cross-site request forgery (CSRF) vulnerability in CRU Ditto Forensic FieldStation with firmware before 2013Oct15a allows remote attackers to hijack the authentication of administrators for requests that modify the disk erase technique settings via unspecified vectors.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-352,

Products Affected

Vendor Product Version
cru-inc ditto_forensic_fieldstation -
cru-inc ditto_forensic_fieldstation_firmware *
CVE-2013-6884 HIGH

The write-blocker in CRU Ditto Forensic FieldStation with firmware before 2013Oct15a has a default "ditto" username and password, which allows remote attackers to gain privileges.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-255,

Products Affected

Vendor Product Version
cru-inc ditto_forensic_fieldstation -
cru-inc ditto_forensic_fieldstation_firmware *