CVE-2018-19010 LOW

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.

CVSS 2.0

Severity: LOW

Problem Type: CWE-20,CWE-20,

Products Affected

Vendor Product Version
draeger infinity_explorer_c700_firmware *
draeger kappa_firmware *
draeger infinity_delta_firmware *
draeger delta_xl_firmware *
CVE-2018-19012 HIGH

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker is able to take control of the operating system.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-269,NVD-CWE-noinfo,

Products Affected

Vendor Product Version
draeger infinity_explorer_c700_firmware *
draeger kappa_firmware *
draeger infinity_delta_firmware *
draeger delta_xl_firmware *
CVE-2018-19014 LOW

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the patient monitor, the location of the monitor, and wired network configuration.

CVSS 2.0

Severity: LOW

Problem Type: CWE-532,CWE-532,

Products Affected

Vendor Product Version
draeger infinity_explorer_c700_firmware *
draeger kappa_firmware *
draeger infinity_delta_firmware *
draeger delta_xl_firmware *
CVE-2021-28111 MEDIUM

Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 2.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-798,

Products Affected

Vendor Product Version
draeger x-dock_firmware *
CVE-2021-28112 MEDIUM

Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 2.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: NVD-CWE-Other,

Products Affected

Vendor Product Version
draeger x-dock_firmware *