Single Connect does not perform an authorization check when using the "log-monitor" module. A remote attacker could exploit this vulnerability to access the logging interface. The exploitation of this vulnerability might allow a remote attacker to obtain sensitive information.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| iletisim@usom.gov.tr | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N | 3.9 | 1.4 |
| nvd@nist.gov | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N | 3.9 | 1.4 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-862,CWE-862,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| krontech | single_connect | * |
Single Connect does not perform an authorization check when using the sc-reports-ui" module. A remote attacker could exploit this vulnerability to access the device configuration page and export the data to an external file. The exploitation of this vulnerability might allow a remote attacker to obtain sensitive information including the database credentials. Since the database runs with high privileges it is possible to execute commands with the attained credentials.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N | 3.9 | 3.6 |
| iletisim@usom.gov.tr | 8.6 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L | 3.9 | 4.7 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-862,CWE-862,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| krontech | single_connect | * |
Single Connect does not perform an authorization check when using the "sc-diagnostic-ui" module. A remote attacker could exploit this vulnerability to access the device information page. The exploitation of this vulnerability might allow a remote attacker to obtain sensitive information.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N | 3.9 | 1.4 |
| iletisim@usom.gov.tr | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N | 3.9 | 1.4 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-862,CWE-862,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| krontech | single_connect | * |
Single Connect does not perform an authorization check when using the "sc-assigned-credential-ui" module. A remote attacker could exploit this vulnerability to modify users permissions. The exploitation of this vulnerability might allow a remote attacker to delete permissions from other users without authenticating.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| nvd@nist.gov | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N | 3.9 | 3.6 |
| iletisim@usom.gov.tr | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N | 3.9 | 1.4 |
CVSS 2.0
Severity: MEDIUM
Problem Type: CWE-862,CWE-862,
Products Affected
| Vendor | Product | Version |
|---|---|---|
| krontech | single_connect | * |
Improper Input Validation, Authorization Bypass Through User-Controlled Key vulnerability in Kron Tech Single Connect on Windows allows Privilege Abuse. This issue affects Single Connect: 2.16.
CVSS 3.x
| Source | Score | Severity | Vector | Exploitability | Impact |
|---|---|---|---|---|---|
| cve@usom.gov.tr | 8.8 | HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H | 2.8 | 5.9 |
| nvd@nist.gov | 8.8 | HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H | 2.8 | 5.9 |
Products Affected
| Vendor | Product | Version |
|---|---|---|
| krontech | single_connect | * |