MidnightBSD

Advisories for mckesson

CVE-2001-1546 MEDIUM

Pathways Homecare 6.5 uses weak encryption for user names and passwords, which allows local users to gain privileges by recovering the passwords from the pwhc.ini file.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 1.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-326,CWE-326,

Products Affected

Vendor Product Version
mckesson pathways_homecare 6.5
CVE-2017-16776 MEDIUM

Security researchers discovered an authentication bypass vulnerability in version 2.0.2 of the Conserus Workflow Intelligence application by McKesson Medical Imaging Company, which is now a Change Healthcare company. The attacker must send a malicious HTTP GET request to exploit the vulnerability. The vulnerability allows an attacker to bypass authentication and escalate privileges of valid users. An unauthenticated attacker can exploit the vulnerability and be granted limited access to other accounts. An authenticated attacker can exploit the vulnerability and be granted access reserved for higher privilege users.

CVSS 2.0

Severity: MEDIUM

Problem Type: NVD-CWE-noinfo,

Products Affected

Vendor Product Version
mckesson conserus_workflow_intelligence 2.0.2
CVE-2018-18630 MEDIUM

A vulnerability was found in McKesson Cardiology product 13.x and 14.x. Insecure file permissions in the default installation may allow an attacker with local system access to execute unauthorized arbitrary code.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 1.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-732,

Products Affected

Vendor Product Version
mckesson horizon_cardiology_firmware 11.0
mckesson cardiology_firmware 13.0
mckesson cardiology_firmware 14.0
changehealthcare cardiology_firmware 14.1.0
mckesson horizon_cardiology_firmware *