CVE-2011-3386 MEDIUM

Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecified vectors involving wireless communications and knowledge of the device's serial number, as demonstrated by Jerome Radcliffe at the Black Hat USA conference in August 2011. NOTE: the vendor has disputed the severity of this issue, saying "we believe the risk of deliberate, malicious, or unauthorized manipulation of medical devices is extremely low... we strongly believe it would be extremely difficult for a third-party to wirelessly tamper with your insulin pump... you would be able to detect tones on the insulin pump that weren't intentionally programmed and could intervene accordingly."

CVSS 2.0

Severity: MEDIUM

Problem Type: NVD-CWE-noinfo,

Products Affected

Vendor Product Version
medtronic paradigm_wireless_insulin_pump 712
medtronic paradigm_wireless_insulin_pump 522
medtronic paradigm_wireless_insulin_pump 722
medtronic paradigm_wireless_insulin_pump 512
CVE-2018-10596 MEDIUM

Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-side (client) service responsible for this HTTP request does not check to ensure it is still connected to the VPN before making the HTTP request. Thus, an attacker could cause the VPN connection to terminate (through various methods and attack points) and intercept the HTTP request, responding with malicious updates via a man-in-the-middle attack. The affected products do not verify the origin or integrity of these updates, as it insufficiently relied on the security of the VPN. An attacker with remote network access to the programmer could influence these communications.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-923,CWE-200,

Products Affected

Vendor Product Version
medtronic 2090_carelink_programmer_firmware *
CVE-2018-10622 LOW

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.

CVSS 2.0

Severity: LOW

Problem Type: CWE-257,CWE-522,

Products Affected

Vendor Product Version
medtronic mycarelink_24952_patient_monitor_firmware -
medtronic mycarelink_24950_patient_monitor_firmware -
CVE-2018-10626 LOW

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.

CVSS 2.0

Severity: LOW

Problem Type: CWE-345,CWE-345,

Products Affected

Vendor Product Version
medtronic mycarelink_24952_patient_monitor_firmware -
medtronic mycarelink_24950_patient_monitor_firmware -
CVE-2018-10631 MEDIUM

The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
134c704f-9b21-4f2e-91b3-4a467353bcc0 6.6 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 0.7 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-693,CWE-693,

Products Affected

Vendor Product Version
medtronic n'vision_8870_firmware -
medtronic n'vision_8840_firmware -
CVE-2018-10634 LOW

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.

CVSS 2.0

Severity: LOW

Problem Type: CWE-319,CWE-319,

Products Affected

Vendor Product Version
medtronic minimed_paradigm_508_insulin_pump_firmware -
medtronic minimed_530g_mmt-751_firmware -
medtronic minimed_530g_mmt-551_firmware -
medtronic minimed_paradigm_real-time_mmt-522_firmware -
medtronic minimed_paradigm_revel_mmt-523k_firmware -
medtronic minimed_paradigm_revel_mmt-723k_firmware -
medtronic minimed_paradigm_revel_mmt-723_firmware -
medtronic minimed_paradigm_real-time_mmt-722_firmware -
medtronic minimed_paradigm_revel_mmt-523_firmware -
CVE-2018-18984 LOW

Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest .

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 4.6 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 0.9 3.6

CVSS 2.0

Severity: LOW

Problem Type: CWE-311,CWE-312,

Products Affected

Vendor Product Version
medtronic 29901_encore_programmer_firmware *
medtronic carelink_9790_programmer_firmware *
medtronic carelink_2090_programmer_firmware *
CVE-2018-5446 LOW

Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.

CVSS 2.0

Severity: LOW

Problem Type: CWE-257,CWE-522,

Products Affected

Vendor Product Version
medtronic 2090_carelink_programmer_firmware *
CVE-2018-5448 LOW

Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.

CVSS 2.0

Severity: LOW

Problem Type: CWE-23,CWE-22,

Products Affected

Vendor Product Version
medtronic 2090_carelink_programmer_firmware *
CVE-2018-8849 LOW

Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.

CVSS 2.0

Severity: LOW

Problem Type: CWE-311,CWE-311,

Products Affected

Vendor Product Version
medtronic n'vision_8870_firmware -
medtronic n'vision_8840_firmware -
CVE-2018-8868 MEDIUM

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-749,NVD-CWE-noinfo,

Products Affected

Vendor Product Version
medtronic 24950_mycarelink_monitor_firmware -
medtronic 24952_mycarelink_monitor_firmware -
CVE-2018-8870 HIGH

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-259,CWE-798,

Products Affected

Vendor Product Version
medtronic 24950_mycarelink_monitor_firmware -
medtronic 24952_mycarelink_monitor_firmware -
CVE-2019-10964 MEDIUM

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-284,CWE-287,CWE-863,

Products Affected

Vendor Product Version
medtronic minimed_paradigm_522k_firmware *
medtronic minimed_paradigm_523_firmware *
medtronic minimed_508_firmware *
medtronic minimed_paradigm_veo_754_firmware *
medtronic minimed_paradigm_723k_firmware *
medtronic minimed_paradigm_veo_754cm_firmware -
medtronic minimed_paradigm_515_firmware *
medtronic minimed_paradigm_712e_firmware *
medtronic minimed_paradigm_715_firmware *
medtronic minimed_paradigm_522_firmware *
medtronic minimed_paradigm_722k_firmware *
medtronic minimed_paradigm_veo_554_firmware *
medtronic minimed_paradigm_veo_554cm_firmware *
medtronic minimed_paradigm_723_firmware *
medtronic minimed_paradigm_712_firmware *
medtronic minimed_paradigm_722_firmware *
medtronic minimed_paradigm_512_firmware *
medtronic minimed_paradigm_511_firmware *
medtronic minimed_paradigm_523k_firmware *
CVE-2019-13531 LOW

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 4.6 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N 0.9 3.6

CVSS 2.0

Severity: LOW

Problem Type: CWE-287,NVD-CWE-noinfo,

Products Affected

Vendor Product Version
medtronic valleylab_ls10_energy_platform_firmware *
medtronic valleylab_ft10_energy_platform_firmware 2.1.0
medtronic valleylab_ft10_energy_platform_firmware 2.0.3
CVE-2019-13535 LOW

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 4.6 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 0.9 3.6

CVSS 2.0

Severity: LOW

Problem Type: CWE-693,CWE-732,

Products Affected

Vendor Product Version
medtronic valleylab_ls10_energy_platform_firmware *
medtronic valleylab_ft10_energy_platform_firmware 2.1.0
medtronic valleylab_ft10_energy_platform_firmware 2.0.3
CVE-2019-13539 HIGH

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 1.8 5.9

CVSS 2.0

Severity: HIGH

Problem Type: CWE-328,CWE-326,

Products Affected

Vendor Product Version
medtronic valleylab_ft10_energy_platform_firmware *
medtronic valleylab_exchange_client *
medtronic valleylab_fx8_energy_platform_firmware *
CVE-2019-13543 MEDIUM

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 3.9 3.6

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-798,CWE-798,

Products Affected

Vendor Product Version
medtronic valleylab_ft10_energy_platform_firmware *
medtronic valleylab_exchange_client *
medtronic valleylab_fx8_energy_platform_firmware *
CVE-2019-6538 LOW

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N 2.8 3.6

CVSS 2.0

Severity: LOW

Problem Type: CWE-284,CWE-306,CWE-862,

Products Affected

Vendor Product Version
medtronic protecta_icd_and_crt-d_firmware -
medtronic mycarelink_monitor_firmware 24950
medtronic concerto_ii_crt-d_firmware -
medtronic maximo_ii_crt-d_and_lcd_firmware -
medtronic mirro_icd_firmware -
medtronic amplia_crt-d_firmware -
medtronic concerto_crt-d_firmware -
medtronic nayamed_nd_icd_firmware -
medtronic compia_crt-d_firmware -
medtronic primo_icd_firmware -
medtronic mycarelink_monitor_firmware 24952
medtronic carelink_2090_firmware -
medtronic consulta_crt-d_firmware -
medtronic visia_af_icd_firmware -
medtronic viva_crt-d_firmware -
medtronic virtuoso_ii_icd_firmware -
medtronic virtuoso_icd_firmware -
medtronic carelink_monitor_firmware 2490c
medtronic claria_crt-d_firmware -
medtronic evera_icd_firmware -
medtronic secura_icd_firmware -
CVE-2019-6540 LOW

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 2.8 3.6

CVSS 2.0

Severity: LOW

Problem Type: CWE-319,CWE-319,

Products Affected

Vendor Product Version
medtronic mycarelink_monitor_24950_firmware -
medtronic concerto_ii_crt-d_firmware -
medtronic maximo_ii_crt-d_firmware -
medtronic mirro_icd_firmware -
medtronic amplia_crt-d_firmware -
medtronic concerto_crt-d_firmware -
medtronic nayamed_nd_icd_firmware -
medtronic compia_crt-d_firmware -
medtronic primo_icd_firmware -
medtronic carelink_2090_firmware -
medtronic consulta_crt-d_firmware -
medtronic visia_af_icd_firmware -
medtronic viva_crt-d_firmware -
medtronic virtuoso_ii_icd_firmware -
medtronic carelink_monitor_2490c_firmware -
medtronic protecta_crt-d_firmware -
medtronic virtuoso_icd_firmware -
medtronic maximo_ii_icd_firmware -
medtronic claria_crt-d_firmware -
medtronic mycarelink_monitor_24952_firmware -
medtronic evera_icd_firmware -
medtronic protecta_icd_firmware -
medtronic secura_icd_firmware -
CVE-2020-25183 MEDIUM

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 2.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-287,CWE-287,

Products Affected

Vendor Product Version
medtronic mycarelink_smart_model_25000_firmware *
CVE-2020-25187 HIGH

Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 3.9 5.9

CVSS 2.0

Severity: HIGH

Problem Type: CWE-122,CWE-787,

Products Affected

Vendor Product Version
medtronic mycarelink_smart_model_25000_firmware *
CVE-2020-27252 HIGH

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H 2.2 5.9

CVSS 2.0

Severity: HIGH

Problem Type: CWE-367,CWE-367,

Products Affected

Vendor Product Version
medtronic mycarelink_smart_model_25000_firmware *
CVE-2022-32537

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance

Products Affected

Vendor Product Version
medtronic guardian_link_3_transmitter_mmt-7810_firmware -
medtronic minimed_670g_mmt-1762_firmware -
medtronic guardian_link_2_transmitter_mmt-7738_firmware -
medtronic minimed_640g_mmt-1751_firmware -
medtronic minimed_640g_mmt-1712_firmware -
medtronic minimed_640g_mmt-1752_firmware -
medtronic minimed_670g_mmt-1741_firmware -
medtronic minimed_630g_mmt-1715_firmware -
medtronic guardian_link_3_transmitter_mmt-7811_firmware -
medtronic minimed_640g_mmt-1711_firmware -
medtronic guardian_link_2_transmitter_mmt-7730_firmware -
medtronic minimed_670g_mmt-1780_firmware -
medtronic guardian_link_2_transmitter_mmt-7731_firmware -
medtronic minimed_670g_mmt-1781_firmware -
medtronic guardian_link_2_transmitter_mmt-7775_firmware -
medtronic minimed_670g_mmt-1760_firmware -
medtronic minimed_670g_mmt-1740_firmware -
medtronic minimed_620g_mmt-1750_firmware -
medtronic minimed_670g_mmt-1742_firmware -
medtronic minimed_670g_mmt-1761_firmware -
medtronic mmt-1351_firmware -
medtronic minimed_630g_mmt-1755_firmware -
medtronic minimed_630g_mmt-1754_firmware -
medtronic mmt-1352_firmware -
medtronic minimed_670g_mmt-1782_firmware -
medtronic mmt-1151_firmware -
medtronic mmt-1152_firmware -
medtronic mmt-7306_firmware -
CVE-2023-25931

Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an individual would need physical access to the Smart Programmer.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
security@medtronic.com 6.4 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H 0.9 5.5
nvd@nist.gov 6.8 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 0.9 5.9

Products Affected

Vendor Product Version
medtronic interstim_x_clinician a51300
medtronic micro_clinician a51200
CVE-2023-31222

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
security@medtronic.com 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 3.9 5.9

Products Affected

Vendor Product Version
medtronic paceart_optima *
CVE-2025-12994

Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
security@medtronic.com 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N 3.9 1.4

Products Affected

Vendor Product Version
medtronic carelink_network *
CVE-2025-12995

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
security@medtronic.com 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H 2.2 5.9

Products Affected

Vendor Product Version
medtronic carelink_network *
CVE-2025-12996

Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
security@medtronic.com 4.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N 0.5 3.6

Products Affected

Vendor Product Version
medtronic carelink_network *
CVE-2025-12997

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
security@medtronic.com 2.2 LOW CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N 0.7 1.4

Products Affected

Vendor Product Version
medtronic carelink_network *