MidnightBSD

Advisories for modernasistemas

CVE-2024-23747

The Moderna Sistemas ModernaNet Hospital Management System 2024 is susceptible to an Insecure Direct Object Reference (IDOR) vulnerability. This vulnerability resides in the system's handling of user data access through a /Modernanet/LAUDO/LAU0000100/Laudo?id= URI. By manipulating this id parameter, an attacker can gain access to sensitive medical information.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 3.9 3.6

Products Affected

Vendor Product Version
modernasistemas modernanet_hospital_management_system_2024 -
CVE-2025-1640 HIGH

A vulnerability was found in Benner ModernaNet up to 1.1.0 and classified as critical. Affected by this issue is some unknown functionality of the file /Home/JS_CarregaCombo?formName=DADOS_PESSOAIS_PLANO&additionalCondition=&insideParameters=&elementToReturn=DADOS_PESSOAIS_PLANO&ordenarPelaDescricao=true&direcaoOrdenacao=asc&_=1739290047295. The manipulation leads to sql injection. The attack may be launched remotely. Upgrading to version 1.1.1 is able to address this issue. It is recommended to upgrade the affected component.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 3.9 5.9
cna@vuldb.com 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L 3.9 3.4

CVSS 2.0

Severity: HIGH

Problem Type: CWE-74,CWE-89,CWE-89,

Products Affected

Vendor Product Version
modernasistemas modernanet *
CVE-2025-1641 HIGH

A vulnerability was found in Benner ModernaNet up to 1.1.0. It has been classified as critical. This affects an unknown part of the file /AGE0000700/GetHorariosDoDia?idespec=0&idproced=1103&data=2025-02-25+19%3A25&agserv=0&convenio=1&localatend=1&idplano=5&pesfis=01&idprofissional=0&target=.horarios--dia--d0&_=1739371223797. The manipulation leads to sql injection. It is possible to initiate the attack remotely. Upgrading to version 1.1.1 is able to address this issue. It is recommended to upgrade the affected component.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
cna@vuldb.com 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L 3.9 3.4
nvd@nist.gov 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 3.9 5.9

CVSS 2.0

Severity: HIGH

Problem Type: CWE-74,CWE-89,CWE-89,

Products Affected

Vendor Product Version
modernasistemas modernanet *
CVE-2025-1642 MEDIUM

A vulnerability was found in Benner ModernaNet up to 1.1.0. It has been declared as critical. This vulnerability affects unknown code of the file /AGE0000700/GetImageMedico?fooId=1. The manipulation of the argument fooId leads to improper control of resource identifiers. The attack can be initiated remotely. Upgrading to version 1.1.1 is able to address this issue. It is recommended to upgrade the affected component.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 3.9 3.6
cna@vuldb.com 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N 2.8 1.4

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-99,NVD-CWE-Other,

Products Affected

Vendor Product Version
modernasistemas modernanet *
CVE-2025-1643 MEDIUM

A vulnerability was found in Benner ModernaNet up to 1.1.0. It has been rated as problematic. This issue affects some unknown processing of the file /DadosPessoais/SG_AlterarSenha. The manipulation leads to cross-site request forgery. The attack may be initiated remotely. Upgrading to version 1.1.1 is able to address this issue. It is recommended to upgrade the affected component.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 2.8 5.9
cna@vuldb.com 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N 2.8 1.4

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-352,CWE-862,CWE-352,

Products Affected

Vendor Product Version
modernasistemas modernanet *
CVE-2025-1644 MEDIUM

A vulnerability classified as problematic has been found in Benner ModernaNet up to 1.2.0. Affected is an unknown function of the file /DadosPessoais/SG_Gravar. The manipulation of the argument idItAg leads to cross-site request forgery. It is possible to launch the attack remotely. Upgrading to version 1.2.1 is able to address this issue. It is recommended to upgrade the affected component.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
cna@vuldb.com 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N 2.8 1.4
nvd@nist.gov 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N 2.8 3.6

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-352,CWE-862,CWE-352,

Products Affected

Vendor Product Version
modernasistemas modernanet *