MidnightBSD

Advisories for rainmachine

CVE-2018-6011 MEDIUM

The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remote and local access, aka a "Use of Password Hash Instead of Password for Authentication" issue. This is exploitable by an attacker who discovers a hash value in the rainmachine-settings.sqlite file.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-287,

Products Affected

Vendor Product Version
rainmachine mini-8_firmware *
CVE-2018-6012 HIGH

The 'Weather Service' feature of the Green Electronics RainMachine Mini-8 (2nd generation) allows an attacker to inject arbitrary Python code via the 'Add new weather data source' upload function.

CVSS 2.0

Severity: HIGH

Problem Type: CWE-94,

Products Affected

Vendor Product Version
rainmachine mini-8_firmware *
CVE-2018-6906 MEDIUM

A persistent Cross Site Scripting (XSS) vulnerability in the Green Electronics RainMachine Mini-8 (2nd Generation) and Touch HD 12 web application allows an attacker to inject arbitrary JavaScript via the REST API.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-79,

Products Affected

Vendor Product Version
rainmachine rainmachine_web_application -
CVE-2018-6907 MEDIUM

A Cross Site Request Forgery (CSRF) vulnerability in the Green Electronics RainMachine Mini-8 (2nd Generation) and Touch HD 12 web application allows an attacker to control the RainMachine device via the REST API.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-352,

Products Affected

Vendor Product Version
rainmachine rainmachine_web_application -
CVE-2018-6908 MEDIUM

An authentication bypass vulnerability exists in the Green Electronics RainMachine Mini-8 (2nd Generation) and Touch HD 12 web application allowing an unauthenticated attacker to perform authenticated actions on the device via a 127.0.0.1:port value in the HTTP 'Host' header, as demonstrated by retrieving credentials.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-287,

Products Affected

Vendor Product Version
rainmachine mini-8_firmware *
rainmachine touch_hd_12_firmware *
CVE-2018-6909 MEDIUM

A missing X-Frame-Options header in the Green Electronics RainMachine Mini-8 (2nd Generation) and Touch HD 12 web application could be used by a remote attacker for clickjacking, as demonstrated by triggering an API page request.

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-1021,

Products Affected

Vendor Product Version
rainmachine rainmachine_web_application -