MidnightBSD

Advisories for se

CVE-2020-7496 MEDIUM

A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
nvd@nist.gov 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 1.8 5.9

CVSS 2.0

Severity: MEDIUM

Problem Type: CWE-88,CWE-88,

Products Affected

Vendor Product Version
se ecostruxure_operator_terminal_expert *
se ecostruxure_operator_terminal_expert 3.1
CVE-2023-37200

A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
cybersecurity@se.com 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N 1.8 3.6

Products Affected

Vendor Product Version
se ecostruxure_opc_ua_server_expert 2.01
se ecostruxure_opc_ua_server_expert *
CVE-2024-0568

CWE-287: Improper Authentication vulnerability exists that could cause unauthorized tampering of device configuration over NFC communication.

CVSS 3.x

Source Score Severity Vector Exploitability Impact
cybersecurity@se.com 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 2.8 5.9

Products Affected

Vendor Product Version
se rmnf22tb30_firmware *
se renf22r2mmw_firmware *